— Knowledge —
— PRODUCTS —
Email:susie@hnljpump.com
Mobile:+8618507312158
TEL:+8613974960765
vertical turbine pump
发布时间:2024/11/20 17:34:34 人气: [content:visits]
Inlet flow disturbances, such as swirl, unbalance in the distribution of velocities and pressures, and sudden variations in velocity can be harmful to the hydraulic performance of a Canned Vertical Turbine Pump (double casing vertical barrel centrifugal pump) , its mechanical behavior, and its reliability.
The minimum required straight pipe length (L2) before pump suction inlet is specified.
The straight pipe section is to be the same diameter as that of the Canned Vertical Turbine Pump (double casing vertical barrel centrifugal pump) section nozzle.
The pipe length L2 depends on the distance between suction nozzle and hydraulic inlet L1 and on the Can inner diameter øD1.
Previous:Initial alignment Of The Vertical Turbine Pumps (VTP pumps)
Next:Installation of couplings on The Vertical Turbine Pump's solid shaft drivers